- Quality of the measurement data is high.
- Origin of the data is Ascend Acoustics.
- Format of the data is a set of 36 horizontal and 36 vertical measurements .
-
Sensitivity:
- Company: 86.0 dB
- Measured: 85.8 dB (avg. 300Hz-3kHz for 2.83V measured at 1m).
- -3dB (resp. -6db) point v.s. reference is at 79.1Hz (resp. 67.4Hz).
- Reference level is normalised to -0.3dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 2.7dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 3.93
and would be 6.55 with a
perfect subwoofer.
- Details: NBD: ON 0.396, LW 0.366, SP 0.393, PIR 0.334; SM: SP0.339, PIR0.368; LFQ 0.902, LFX 58Hz
- Tonality (Preference) Score is 5.46
with an EQ and would be 7.71 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.278, LW 0.241, SP 0.314, PIR 0.227; SM: SP0.451, PIR0.604; LFQ 0.902, LFX 48Hz
- Tonality (Preference) Score is 3.93
and would be 6.55 with a
perfect subwoofer.